Engineering Specification :
THE BASIC SERIES LIQUID FLOW RATE METER SHALL:
  • Use the variable annular orifice technique with compression spring recoil.
  • Not require inlet or outlet straight plumbing, or require vertical pipe mounting.
  • Have a measuring accuracy of ±2.5% of full scale in the center third of the measuring range, and ±4% in upper and lower thirds.
  • Have a stainless steel sharp-edged orifice.
  • Have weather-tight external construction.
  • Be Lake Monitors No. B _ _ – _ _ _ – _ _
 
hi-temp

High Temperature Flow Rate Meters

For 1/8"- 2" Pipe Sizes Style H & J
Enables flow monitoring of barrel heating fluids, thermal transfer fluids such as Syltherm® coolant flows through heat exchangers, as well as flows through hydraulic circuits and sub-circuits with elevated temps.

Engineering Specification :
THE HIGH TEMPERATURE IN-LINE FLOW RATE METER SHALL:

  • Use the variable annular orifice technique with compression spring recoil.
  • Not require inlet or outlet straight plumbing, or require vertical pipe mounting.
  • Have a measuring accuracy of ±2.5% of full scale in the center third of the measuring range, and ±4% in upper and lower thirds.
  • Have a stainless steel sharp-edged orifice.
  • Have a maximum temperature rating of: H-series 400°F (204°C) or J-series 600°F (315°C).
  • Have a working pressure rating of 3500 PSIG.
  • Be Lake Monitors No. H _ _ – _ _ _ – _ _ for 400°F (204°C) applications
    or J _ _ – _ _ _ – _ _ for 600°F (315°C) applications.
 
phospate

Phosphate Ester Flow Rate Meters
For 1/8"- 2" Pipe Sizes
Style P

Compatible with aviation lubricants such as Skydrol®, as well as fire-retardant fluids such as Pydraul®, Fyrquel® and Houghton 900® series.
Engineering Specification :
THE PHOSPHATE ESTER IN-LINE FLOW RATE METER SHALL:

  • Include a direct-reading scale corrected for phosphate ester media.
  • Use the variable annular orifice technique with compression spring recoil.
  • Not require inlet or outlet straight plumbing, or require vertical pipe mounting.
  • Have a measuring accuracy of ±2.5% of full scale in the center third of the measuring range, and ±4% in upper and lower thirds.
  • Have a stainless steel sharp-edged orifice.
  • Be Lake Monitors No. P _ _ – _ _ _ – _ _
 
pneumatic

Pneumatic Flow Rate Meters
For 1/8"- 2" Pipe Sizes
Style G
Ideal for monitoring air compressor outputs, pneumatic tool consumption and industrial gas flows.

Engineering Specification
THE PNEUMATIC IN-LINE FLOW RATE METER SHALL:

  • Use the variable annular orifice technique with compression spring recoil.
  • Not require inlet or outlet straight plumbing, or require vertical pipe mounting.
  • Have a measuring accuracy of ±2.5% of full scale in the center third of the measuring range, and ±4% in upper and lower thirds.
  • Have a stainless steel sharp-edged orifice.
  • Have a weather-tight external construction.
  • Be Lake Monitors No. G _ _ – _ _ _ – _ _
 
bi-directional

Bi-Directional / Reverse Flow Meters

Lake’s patented technology offers true bi-directional flow measurement for liquids and gasses. For convenient installation and maintenance, there’s no straight pipe mounting or power supply required. And they’re available in aluminum, brass and stainless steel for compatibility with most media.
Lake’s Bi-Directional meters accurately measures flows:
  • In systems with pressure of up to 6000 PSIG
  • Up to 15 GPM in 1/4" - 1/2" diameter pipes
  • Up to 30 GPM in 3/4" - 1" diameter pipes
  • Up to 100 GPM in 1-1/4" - 2" diameter pipes

Last update January 14, 2010