EX810 1000A Clamp Meter with IR : Clamp-on multimeter with built-in non-contact InfraRed Thermometer
EX810-NISTL 1000A Clamp Meter with IR with NIST : Clamp-on multimeter with built-in non-contact InfraRed Thermometer NISTL Certificate Included.
EX810-NIST 1000A Clamp Meter with IR with NIST : Clamp-on multimeter with built-in non-contact InfraRed Thermometer
Features:
- AC Current
- Average Responding
- Non-contact InfraRed Temperature measurements with laser pointer
- Peak hold captures inrush currents and Transients
- MultiMeter functions include
- AC/DC Voltage, Resistance, Capacitance, Frequency, Diode, and Continuity
- 1.7" (43mm) jaw opening for conductors up to 750MCM or two 500MCM
- 4000 count backlit dual display
- Features include Data Hold and Min/Max
- Autoranging with manual range button
- Auto Power off
General Specifications |
| IR Temperature |
-58 to 518ºF -50 to 270ºC |
| AC Current |
0.1 to 1000A |
| DC Current |
NA |
| AC Voltage |
0.1mV to 600V |
| DC Voltage |
0.1mV to 600V |
| Resistance |
0.1 to 40M Ω; |
| Capacitance |
0.001nF to 40,000µF |
| Frequency |
0.001kHz to 4kHz |
| Type K Temperature |
NA |
| Continuity |
Yes |
| Inrush |
Yes |
| Diode |
Yes |
| Dimensions/Wt. |
10.6x4.3x2" (270x110x50mm) |
| Weight |
13.6oz (386g) |
|
|
EX830 1000A Clamp Meters with IR Thermometer : Clamp-on multimeter with built-in non-contact InfraRed Thermometer
EX830-NISTL 1000A Clamp Meters with IR Thermometer with NIST : Clamp-on multimeter with built-in non-contact InfraRed Thermometer NISTL Certificate Included
Features:
- AC Current
- True RMS
- Type K Thermometer
- DC Zero
- Non-contact InfraRed Temperature measurements with laser pointer
- Peak hold captures inrush currents and Transients
- MultiMeter functions include
- AC/DC Voltage, Resistance, Capacitance, Frequency, Diode, and Continuity
- 1.7" (43mm) jaw opening for conductors up to 750MCM or two 500MCM
- 4000 count backlit dual display
- Features include Data Hold and Min/Max
- Autoranging with manual range button
- Auto Power off
- Complete with test leads, 9V battery, Type K probe (-4 to 482°F/-20 to 250°C), and belt holster
General Specifications |
| IR Temperature |
-58 to 518ºF -50 to 270ºC |
| AC Current |
0.1 to 1000A |
| DC Current |
0.1 to 1000A |
| AC Voltage |
0.1mV to 600V |
| DC Voltage |
0.1mV to 600V |
| Resistance |
0.1 to 40M Ω; |
| Capacitance |
0.001nF to 40,000µF |
| Frequency |
0.001kHz to 4kHz |
| Type K Temperature |
-4 to 1400°F -20 to 760°C |
| Continuity |
Yes |
| Inrush |
Yes |
| Diode |
Yes |
| Dimensions/Wt. |
10.6x4.3x2" (270x110x50mm) |
| Weight |
13.6oz (386g) |
|
|
382097 100A Current Clamp Probes Set of 3 Current Clamp Probes
Description:
382097: 100A Current Clamp Probes Set of 3 Current Clamp Probes Features:
■1.2" (30mm) jaw size
■100A Max Current
|
|
MA150-NIST 200A Mini AC Clamp Meter + NCV Detector : Compact size AC Clamp meter with built-in AC Voltage detector and Flashlight NIST Certificate Included.
MA150 200A Mini AC Clamp Meter + NCV Detector : Compact size AC Clamp meter with built-in AC Voltage detector and Flashlight
Description:
MA150: 200A Mini AC Clamp Meter + NCV Detector Compact size AC Clamp meter with built-in AC Voltage detector and Flashlight Features:
■0.7" (18mm) jaw opening
■2000 count backlit LCD display
■Non-contact AC Voltage detector (100 to 600VAC) via clamp tip
■Built-in white LED flashlight
■Continuity and Diode Test, Max Hold, Auto power off
■NIST Certificate Included.
|
|
AM300-NIST 300A AC Analog Clamp Meter : Analog AC Clamp Meter with Rotary Scale and Pointer Lock NIST Certificate Included.
AM300 300A AC Analog Clamp Meter : 300A AC Analog Clamp Meter Analog AC Clamp Meter with Rotary Scale and Pointer Lock
* Single function/range switch for easy one hand operation * Rotary Scale with Pointer Lock freezes the reading on the display * Jaw opens to 1.5" (38mm) * AC/DC Voltage and Resistance measurement * Zero adjust *NIST Certificate Included.
|
|
MA200-NIST 400A AC Clamp Meter NIST Certificate Included.
MA200 400A AC Clamp Meter
General Specifications |
| AC Current |
2, 20, 200, 400A (0.001A) |
| DC Current |
NA |
| Basic accuracy |
±2.5% |
| DC Voltage |
200mV, 2V, 20, 200V, 600V (0.1mV) |
| AC Voltage |
200mV, 2V, 20V, 200V, 600V (0.1mV) |
| Basic accuracy |
AC: ±1.5% DC: ±1.2% |
| Resistance (?;) |
200, 2k, 20k, 200k, 2M, 20M (0.1 ‰ ) |
| Capacitance |
NA |
| Frequency |
NA |
| Temperature |
NA |
| Duty Cycle |
NA |
| Continuity |
Beeper =30 ?; |
| Power |
Two AAA batteries |
| Dims/Wt. |
7.9x2x1.4" (200x50x35mm)/ 7oz |
|
|
MA220 400A AC/DC Clamp Meter : Functions include Capacitance, Frequency, Temperature, and Duty Cycle
MA220-NIST 400A AC/DC Clamp Meter : Functions include Capacitance, Frequency, Temperature, and Duty Cycle NIST Certificate Included.
General Specifications |
| AC Current |
2, 20, 200, 400A (0.001A) |
| DC Current |
40, 400A (0.01A) |
| Basic accuracy |
±2.5% |
| DC Voltage |
200mV, 2V, 20, 200V, 600V (0.1mV) |
| AC Voltage |
200mV, 2V, 20V, 200V, 600V (0.1mV) |
| Basic accuracy |
AC: ±1.5% DC: ±1.2% |
| Resistance (Ω;) |
200, 2k, 20k, 200k, 2M, 20M (0.1 ‰ ) |
| Capacitance |
40nF, 400nF, 4μF, 40μF, 100μF (0.01nF) |
| Frequency |
5Hz, 50Hz, 500Hz, 5kHz, 150kHz (0.001Hz) |
| Temperature |
-58 to 1830°F (-50 to 1000°C) (1°) |
| Duty Cycle |
0.5 to 99.0% (0.1%) |
| Continuity |
Beeper ≤30 Ω; |
| Power |
Two AAA batteries |
| Dims/Wt. |
7.9x2x1.4" (200x50x35mm)/ 7oz |
|
|
DC400 400A DC Mini Clamp Meter : Ideal for automotive, heavy equipment and marine DC current measurements
Description:
DC400: 400A DC Mini Clamp Meter Ideal for automotive, heavy equipment and marine DC current measurements Features:
■High Accuracy and Resolution
■One touch "Auto Zero"
■Large 4000 count LCD display
■Easy to use, single function meter |
|
EX612 400A Dual Input AC Clamp Meter + NCV : AC Clamp-on meter with built-in dual Thermocouple inputs and Non-contact Voltage Detector.
EX612-NIST 400A Dual Input AC Clamp Meter + NCV : AC Clamp-on meter with built-in dual Thermocouple inputs and Non-contact Voltage Detector NIST Certificate Included.
Description:
EX612: 400A Dual Input AC Clamp Meter + NCV AC Clamp-on meter with built-in dual Thermocouple inputs and Non-contact Voltage Detector Features:
■True RMS measurements for accurate AC Voltage and Current measurements
■Dual type K thermocouple input with Differential Temperature function (T1, T2, T1-T2) ■Built-in non-contact Voltage detector with LED alert
■DC µA multimeter function for HVAC flame rod Current measurements
■Data Hold plus fast Peak Hold of current surges during motor startup
■40,000 count multimeter functions for DC Voltage, Resistance, Capacitance, and Frequency for high resolution over wider ranges
■Measures motor capacitors to 40,000µF
■1.25" (32mm) jaw opening for conductors up to 500MCM
■Rugged double molded housing
■Auto power off with audible alert and disable function
■Autoranging with manual override
■Complete with CAT III-600V, double molded test leads, 9V battery, two Type K bead wire probes and case |
|
EX622-NISTL AC Clamp-on meter with built-in dual Thermocouple inputs, NCV Detector and InfraRed Thermometer NIST Certificate Included.
EX622 AC Clamp-on meter with built-in dual Thermocouple inputs, NCV Detector and InfraRed Thermometer
Description:
EX622: 400A Dual Input AC Clamp Meter + NCV + IR Thermometer AC Clamp-on meter with built-in dual Thermocouple inputs, NCV Detector and InfraRed Thermometer Features:
■True RMS measurements for accurate AC Voltage and Current measurements
■Dual type K thermocouple input with Differential Temperature function (T1, T2, T1-T2) ■Built-in non-contact IR Thermometer with laser pointer for locating hot spots (up to 518°F/270°C)
■Built-in non-contact Voltage detector with LED alert
■DC µA multimeter function for HVAC flame rod Current measurements
■Data Hold plus fast Peak Hold of current surges during motor startup
■40,000 count multimeter functions for DC Voltage, Resistance, Capacitance, and Frequency for high resolution over wider ranges
■Measures motor capacitors to 40,000µF
■1.25" (32mm) jaw opening for conductors up to 500MCM
■Rugged double molded housing
■Auto power off with audible alert and disable function
■Autoranging with manual override
■8 to 1 distance to target ratio
■Complete with CAT III-600V, double molded test leads, 9V battery, two Type K bead wire probes and case |